Multimeter Fluke 117 ACA/DCA/ACV/DCV/R/F/C TRMS bargraph CAT III 600V

  • SKU: FLUKE 117
  • Fluke
Pealadu
Tallinn, Peterburi tee 90F
0 pcs
Peterburi tee Oomipood
Tallinn, Peterburi tee 90F
1 pcs
Järve keskuse Oomipood
Tallinn, Pärnu mnt. 238
1 pcs
Lõunakeskuse Oomipood
Tartu, Lääneringtee 39
1 pcs
Põhjakeskuse Oomipood
Rakvere, Haljala tee 4
0 pcs
Kaubamajaka Oomipood
Pärnu, Papiniidu 8
0 pcs
Pargi keskuse Oomipood
Jõhvi, Puru tee 1
0 pcs

Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.


Engineered and tested with your safety on the job in mind


Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.


Features


VoltAlert™ technology for non-contact voltage detection

AutoVolt automatic ac/dc voltage selection

LoZ: helps prevent false readings due to ghost voltage

Large white LED backlight to work in poorly lit areas

True-rms for accurate measurements on non-linear loads

Measures 10 A (20 A overload for 30 seconds)

Resistance, continuity, frequency and capacitance

Min/max/average to record signal fluctuations

Compatible with optional magnetic hanger (ToolPak™) for hands free operation

Accurate and easy-to-use

Provides low input impedance to help prevent false readings due to ghost voltage

CAT III 600 V safety rated

DC millivolts

Range 600.0 mV

Resolution 0.1 mV

Accuracy ±0.5% of reading + 2 counts

DC Volts

Range 6.000 V

60.00 V

600.0 V

Resolution 0.001 V

0.01 V

0.1 V

Accuracy ±0.5% of reading + 2 counts

Auto Volts

Range 600 mV

Resolution 0.1 mV

Accuracy 2% + 3 (dc. 45 to 500 Hz)

4% + 3 (500 Hz to 1 kHz)

AC millivolts True RMS

Range 600.0 mV

Resolution 0.1 mV

Accuracy 45 to 500 Hz: ±1.0% of reading + 3 counts

500 Hz to 1 kHz: ±2.0% of reading + 3 counts

AC Volts True RMS

Range 6.000 V

60.00 V

600.0 V

Resolution 0.001 V

0.01 V

0.1 V

Accuracy 45 to 500 Hz: ±1.0% of reading + 3 counts

500 Hz to 1 kHz: ±2.0% of reading + 3 counts

Continuity

Range 600 Ω

Resolution 1 Ω

Accuracy Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer

Ohms

Range 600 Ω

6 kΩ

60 kΩ

600 kΩ

6 MΩ

40 MΩ

Resolution 0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

Accuracy 0.9% + 1

Diode Test

Range 2 V

Resolution 0.001 V

Accuracy 0.9% + 2

Capacitance

Range 1000 nF

10 µF

100 µF

9999 µF

100 to 1000 µF

>1000 µF

Resolution 1 nF

0.01 µF

0.1 µF

1 µF

Accuracy 1.9% + 2

1.9% + 2

5% + 20

Lo-Z Capacitance

Range 1 nF to 500 µF

Accuracy 10% + 2 typical

AC Amps True RMS (45 to 500 Hz)

Range 6.000 A

10.00 A

20 A overload for 30 seconds maximum

Resolution 0.001 A

0.01 A

Accuracy ±1.5% of reading + 3 counts

AC µAmps True RMS (45 Hz to 1 kHz)

Range 600.0 µA

Resolution 0.1 µA

Accuracy ±1.5% of readings + 3 counts (±2.5% of readings + 3 counts >500 Hz)

DC Amps

FLUKE 117 datasheet EN731.71KBDownload
Kiirjuhis multimeetrite ja ampertangide kasutamiseks ET235.34KBDownload
FLUKE 115C/117C User Manual EN645.68KBDownload