Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.
Engineered and tested with your safety on the job in mind
Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.
Features
VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/max/average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
Accurate and easy-to-use
Provides low input impedance to help prevent false readings due to ghost voltage
CAT III 600 V safety rated
DC millivolts
Range 600.0 mV
Resolution 0.1 mV
Accuracy ±0.5% of reading + 2 counts
DC Volts
Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy ±0.5% of reading + 2 counts
Auto Volts
Range 600 mV
Resolution 0.1 mV
Accuracy 2% + 3 (dc. 45 to 500 Hz)
4% + 3 (500 Hz to 1 kHz)
AC millivolts True RMS
Range 600.0 mV
Resolution 0.1 mV
Accuracy 45 to 500 Hz: ±1.0% of reading + 3 counts
500 Hz to 1 kHz: ±2.0% of reading + 3 counts
AC Volts True RMS
Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy 45 to 500 Hz: ±1.0% of reading + 3 counts
500 Hz to 1 kHz: ±2.0% of reading + 3 counts
Continuity
Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer
Ohms
Range 600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
40 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy 0.9% + 1
Diode Test
Range 2 V
Resolution 0.001 V
Accuracy 0.9% + 2
Capacitance
Range 1000 nF
10 µF
100 µF
9999 µF
100 to 1000 µF
>1000 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy 1.9% + 2
1.9% + 2
5% + 20
Lo-Z Capacitance
Range 1 nF to 500 µF
Accuracy 10% + 2 typical
AC Amps True RMS (45 to 500 Hz)
Range 6.000 A
10.00 A
20 A overload for 30 seconds maximum
Resolution 0.001 A
0.01 A
Accuracy ±1.5% of reading + 3 counts
AC µAmps True RMS (45 Hz to 1 kHz)
Range 600.0 µA
Resolution 0.1 µA
Accuracy ±1.5% of readings + 3 counts (±2.5% of readings + 3 counts >500 Hz)