SKU:LCM-25DA
HQAC1029 LED power supply with selectable output current - 25 W - selectable output current PFC
Image is for illustrative purposes only
Output current selectable by DIP switches 180-277 VAC input only built-in active PFC function protection against: short circuit / over-temperature cooling: free air convection fully isolated plastic case Class II power unit, no FG (frame ground).
Built-in DALI interface and push dimming function IP20 no-load power consumption: < 0.5 W power supply synchronization function up to 10 units.
Suitable for indoor LED lighting applications 3 years warranty.
Primary colours: Grey
Additional colours: Blue
Depth unit: 10.5 cm
Height unit: 2.3 cm
Width unit: 6.8 cm
Weight unit: 180 g
Material: Plastic + PS/LED
Standby power consumption: 0.5 W
Environment specifications: li>operating temperature: -30 to +60 °C operating humidity: 20-90 % RH non-condensing storage: -40 to +80 °C, 10-95 % RH temperature coefficient: ± 0.03 %/°C (0-50 °C) vibration: 10-500 Hz, 2G 10 min/1cycle, period for 60 min each along X, Y, Z
Functionality specifications: auxiliary power: 12 V @ 50 mA for driving fan; tolerance ± 5 % temperature compensation: by external NTC thermistor (not provided with the power supply) dimming synchronization
Input specifications: voltage range: 180-277 VAC 254-392 VDC frequency range: 47-63 Hz power factor (typ.): >= 0.975 / 230 VAC; >= 0.96 / 277 VAC at rated power total harmonic distortion: lower than 20 % when output load is 75 % or higher efficiency (typ.): 86 % AC current (typ.): 0.17 A / 230 VAC; 0.15 A / 277 VAC inrush current (typ.): cold start 20 A (twidth = 260 µs measured at 50 % Ipeak) at 230 VAC leakage current: < 0.5 mA / 240 VAC
Mean time between failures (MTBF): MTBF: min. 213.3 Kh; MIL-HDBK-217F (25 °C)
Protection specifications: short circuit: constant current limiting, recovers automatically after fault condition is removed overvoltage: 110-130 V protection type: shut down output voltage, re-power on to recover over-temperature: shut down output voltage, re-power on to recover
Safety and EMC specifications: safety standards: UL8750, CSA C22.2 NO. 250.0-08, ENEC EN61347-1, EN61347-2-13, EN62384 independent approved withstand voltage: input to output: 3.75 kVAC isolation resistance: input to output: > 100 Mohm / 500 VDC / 25 °C / 70 % RH EMC emission: compliance to EN55015, EN61000-3-2 Class C (>= 40 % rated power); EN61000-3-3 EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2 kV), criteria A
Power rating: 25 W
Output specifications: selectable current: 350 mA / 500 mA / 600 mA / 700 mA / 900 mA / 1050 mA DC voltage range: 6-54 V / 6-50 V / 2-67 V / 6-42 V / 6-36 V / 6-28 V/ 6-24 V rated power: 25 W ripple current: ± 5.0 % ripple & noise (max.): 400 mVp-p no-load output voltage (max.): 59 V / 41 V current accuracy: ± 5.0 % setup, rise time: 500 ms, 50 ms / 230 VAC at rated power hold up time (typ.): 30 ms / 230 VAC at rated power
Dimming type: Push dimming
Usage location: Indoor only
Interface type: Build-in dali
powersupplya4v04.pdf