Oomipood

KOGUSELISED SOODUSTUSED

MIDA ROHKEM, SEDA SOODSAM!

PÜSIKLIENDI SOODUSTUSED

TAVAHINNAST VÄHEMALT -5%

PAKK DPD AUTOMAATI TASUTA

EESTI PIIRES ÜLE 50€ TELLIMUSTELE

Kodumasinate varuosapäring. Esita päring.
  

Pilt on illustratiivne

Taimer 12V 10A 250V karbiga

  • Tootekood: DK-C-05

Features:
1. Output optocoupler isolation to enhance anti-interference ability power consumption.
2. Industrial grade circuit board, set the parameters for permanent memory after power off.
3. The relay output is a passive contact, with no power output, controlling the function of a line.
4. Can control devices within 30V 5A or within 220V 5A.

Operating mode:
P-1: The signal triggers the relay to pull in and closes.
During the delay period A: Invalid again,
            C: Trigger re-clocking again,
            E: Trigger relay reset termination timing again.

P-2: Signal trigger start timing time T1, time is up to relay pull-in time T2 disconnect (reset).
A: Invalid again,
C: Trigger re-clocking again,
E: Start delay without triggering power on.

P-3: Cycling: Turn on T1, disconnect T2, infinite loop.
The time of T1 and T2 is adjustable. If a parameter is turned on or off to 0, the power-on delay can be turned on or the power-on time-delay power-off does not cycle.
A: The relay is turned on immediately after power-on,
C: The relay is turned off and then turned on after power-on.

P-4: There is signal, the relay is closed, the suction is kept, the signal disappears, the timing starts, the time is up, the relay is disconnected.
During the delay, the signal is given again, the delay is cancelled, the relay is held, the signal disappears, and the timer is re-timed.

Key setting:
K1: Function selection button: Press and hold the K1 button for 2 seconds, P-* appears, short press K1 to select the mode, press K2 to enter the mode.

K2: Shift key: Press to adjust the flashing position of the digital tube, K3 adjusts the value of the digital tube flashing digital tube. Until K2 is pressed, the digital tube no longer flashes, the setup time is completed, the setup time is automatically saved and the power is turned off.

K3: When the digital tube is flashing: K3 adjusts the digital change, and 0 to 9 change sequentially.
When the digital tube display is normal: K3 adjusts the decimal point position, the decimal point represents 0 to 999 minutes in ones digit; 0 to 99.9 seconds in ten digits; 0 to 999 seconds in no decimal point

Material: alloy casing + ABS
Working voltage: DC DC 12V
Quiescent current: 20mA
Working current: 50mA
Signal source: positive trigger, PNP, active high
Service life: about 100,000 times
Working temperature: -30~85°C
Size: 64mm*34mm*18mm/2.51*1.33*0.71\'\'
Weight: 44g

Warning Note:
Note 1: After the working mode is selected, short press K3 to enter the function A, C, E switch, the digital tube will briefly display A or C or E, the default is A, press K2 to confirm the setting.
Note 2: Functions P-2 and P-3 have two sets of time to be adjusted. Press K2 six times for one cycle, the first three times to adjust one time, and the last three times to adjust another time.
Note 3: The blue light indicates the time when the relay is closed, and the blue light indicates the time when the relay is turned off.