OMRON INDUSTRIAL AUTOMATION – E53-CN03N2 – ACCESSORY, E5CN
SKU:1708026
The OMRON INDUSTRIAL AUTOMATION E53-CN03N2 option unit provides robust RS-485 communications, enhancing your E5CN series controllers. This unit enables efficient process management and reliable data communication over long distances, facilitating seamless integration into industrial automation systems.
Key Features - RS-485 communication interface
- Enables digital signalling for precise data exchange
- Simplifies integration with various industrial automation setups
- Compatible with a wide array of applications and systems
- Logic operations and preventive maintenance functions
- High resolution, high speed and high input accuracy
- Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions
- Heater burnout detection (including SSR failure and heater overcurrent detection)
- 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions
- Control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program and automatic cooling coefficient adjustment
- High-resolution display with 5 digits/0.01°C
- Flexible contact outputs with logic operations (AND or and delays) set from the support software (CX-Thermo Ver. 4.0)
- Preventive maintenance for relays using a control output ON/OFF counter
Use Cases and Benefits - Remote monitoring of temperature controllers
- Connection to supervisory control and data acquisition (SCADA) systems
- Facilitates communication in process control environments
- Suitable for automated machinery requiring robust signalling solutions
- Used with temperature controllers for remote monitoring
- Enables connection to supervisory control and data acquisition systems
- Facilitates communication in process control environments
- Suitable for automated machinery requiring robust signalling solutions
Compatibility - E5CN-H Series Temperature Controllers
- New E5CN-H models released after January 2008
Software Support - CX-Thermo version 4.0 or higher
- Supports Windows XP/Vista/7/8 OS
Key Features - RS-485 communication interface
- Enables digital signalling for precise data exchange
- Simplifies integration with various industrial automation setups
- Compatible with a wide array of applications and systems
- Logic operations and preventive maintenance functions
- High resolution, high speed and high input accuracy
- Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions
- Heater burnout detection (including SSR failure and heater overcurrent detection)
- 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions
- Control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program and automatic cooling coefficient adjustment
- High-resolution display with 5 digits/0.01°C
- Flexible contact outputs with logic operations (AND or and delays) set from the support software (CX-Thermo Ver. 4.0)
- Preventive maintenance for relays using a control output ON/OFF counter
Use Cases and Benefits - Remote monitoring of temperature controllers
- Connection to supervisory control and data acquisition (SCADA) systems
- Facilitates communication in process control environments
- Suitable for automated machinery requiring robust signalling solutions
- Used with temperature controllers for remote monitoring
- Enables connection to supervisory control and data acquisition systems
- Facilitates communication in process control environments
- Suitable for automated machinery requiring robust signalling solutions
Compatibility - E5CN-H Series Temperature Controllers
- New E5CN-H models released after January 2008
Software Support - CX-Thermo version 4.0 or higher
- Supports Windows XP/Vista/7/8 OS
Accessory Type: Option Card, Communications
Dielectric strength: 2300VAC 50 or 60Hz for 1 minute
Input sampling period: 250 ms
Insulation resistance: 20MΩ minimum at 500VDC
Operating Temperature Max: 55°C
Operating Temperature Min: -10°C
Specifications: RS-485
Dielectric strength: 2300VAC 50 or 60Hz for 1 minute
Input sampling period: 250 ms
Insulation resistance: 20MΩ minimum at 500VDC
Operating Temperature Max: 55°C
Operating Temperature Min: -10°C
Specifications: RS-485